DETAILS
Our premium copper coated, low alloy MIG wire manufactured to meet tensile strength requirements of 80,000 to 90,000 psi (552-620 MPa) minimum.
Features
- Capable of producing weld deposits with 550 - 620 MPa (80 - 90 ksi) tensile strength
- Contains 0.50% molybdenum for strength after stress-relief
- Microguard® Ultra provides superior feeding and arc stability
- Supports short-circuiting, globular, axial spray and pulsed spray transfer
Typical Applications
- Requirements for strength after stress relieving
- ASTM A182, A217, A234 and A335 high temperature service pipe, fittings, flanges and valves
- ASTM A336 pressure vessel forgings
Welding Positions
- All
Shielding Gas
- Mixed Shielding Gas|100% CO2
Service Information
Documentation
You May Also Need
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.28 | ER80S-D2, ER90S-D2 |
CWB | CWB AWS A5.28 | ER55S-D2 (ER80S-D2), ER62S-D2 (ER90S-D2) |
MIL | MIL-E-23765/2E | MIL-80S-3 |
MECHANICAL PROPERTIES
Classification | Shielding Gas | Polarity |
Yield Strength @ 0.2% Offset
MPa (ksi) |
Tensile Strength
MPa (ksi) |
Elongation
% |
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F) |
---|---|---|---|---|---|---|
ER80S-D2 Requirement | 100% CO2 | DC+ | 470 (68) min. | 550 (80) min. | 17 min. | 27 (20) min. |
ER90S-D2 Requirement | 1-5% O2, balance Ar | DC+ | 540 (78) min. | 620 (90) min. | 17 min. | 27 (20) min. |
Typical Result, As-welded | 100% CO2 | DC+ | 510 (74) | 610-670 (88-96) | 17 | 27-103 (20-76) |
Typical Result, As-welded | 95% Ar, 5% O2 | DC+ | 540 (79) | 640-670 (93-97) | 24 | 74-205 (55-151) |
Typical Result, As-welded | 98% Ar, 2% O2 | DC+ | 610 (88) | 680-740 (99-107) | 23 | 96-183 (71-135) |
WIRE COMPOSITION
Classification | %C | %Cr | %Mn | %Mo | %Ni | %P | %S | %Si | %Total Cu |
---|---|---|---|---|---|---|---|---|---|
ER90S-D2 Requirement | 0.07 - 0.12 | 1.60 - 2.10 | 0.40 - 0.60 | 0.15 max. | 0.025 max. | 0.025 max. | 0.50 - 0.80 | 0.50 max. | |
Typical Result | 0.07-0.10 | 0.02 | 1.69-1.87 | 0.44-0.51 | 0.01-0.02 | 0.006-0.009 | 0.004-0.011 | 0.57-0.70 | 0.14-0.23 |
TYPICAL OPERATING PROCEDURES
Diameter | Transfer Mode | Shielding Gas | Polarity |
CTWD
mm (in.)⁽¹⁾ |
Wire Feed Speed
m/min (in/min) |
Voltage
volts |
Approx. Current
amps |
Melt-off Rate
kg/hr (lb/hr) |
---|---|---|---|---|---|---|---|---|
0.035 in (0.9 mm) | Short Circuit Transfer ⁽²⁾ | 75% Ar / 25% CO2 | DC+ | 9-12 (3/8-1/2) | 2.5 (100) | 18 | 80 | 0.7 (1.6) |
0.035 in (0.9 mm) | Short Circuit Transfer ⁽²⁾ | 75% Ar / 25% CO2 | DC+ | 9-12 (3/8-1/2) | 3.8 (150) | 19 | 120 | 1.1 (2.4) |
0.035 in (0.9 mm) | Short Circuit Transfer ⁽²⁾ | 75% Ar / 25% CO2 | DC+ | 9-12 (3/8-1/2) | 6.4 (250) | 22 | 175 | 1.8 (4.0) |
0.035 in (0.9 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-19 (1/2-3/4) | 9.5 (375) | 23 | 195 | 2.7 (6.0) |
0.035 in (0.9 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-19 (1/2-3/4) | 12.7 (500) | 29 | 230 | 3.6 (8.0) |
0.035 in (0.9 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-19 (1/2-3/4) | 15.2 (600) | 30 | 275 | 4.4 (9.6) |
0.045 in (1.1 mm) | Short Circuit Transfer ⁽²⁾ | 75% Ar / 25% CO2 | DC+ | 12-19 (1/2-3/4) | 3.2 (125) | 19 | 145 | 1.5 (3.4) |
0.045 in (1.1 mm) | Short Circuit Transfer ⁽²⁾ | 75% Ar / 25% CO2 | DC+ | 12-19 (1/2-3/4) | 3.8 (150) | 20 | 165 | 1.8 (4.0) |
0.045 in (1.1 mm) | Short Circuit Transfer ⁽²⁾ | 75% Ar / 25% CO2 | DC+ | 12-19 (1/2-3/4) | 5.1 (200) | 21 | 200 | 2.5 (5.4) |
0.045 in (1.1 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-19 (1/2-3/4) | 8.9 (350) | 27 | 285 | 4.2 (9.2) |
0.045 in (1.1 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-19 (1/2-3/4) | 12.1 (475) | 30 | 335 | 5.7 (12.5) |
0.045 in (1.1 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-19 (1/2-3/4) | 12.7 (500) | 30 | 340 | 6.0 (13.2) |
0.052 in (1.3 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-19 (1/2-3/4) | 7.6 (300) | 30 | 300 | 4.8 (10.6) |
0.052 in (1.3 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-19 (1/2-3/4) | 8.1 (320) | 30 | 320 | 5.2 (11.5) |
0.052 in (1.3 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-19 (1/2-3/4) | 12.3 (485) | 32 | 430 | 7.8 (17.1) |
1/16 in (1.6 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-25 (1/2-1) | 5.3 (210) | 25 | 325 | 4.8 (10.7) |
1/16 in (1.6 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-25 (1/2-1) | 6.0 (235) | 27 | 350 | 5.4 (12.0) |
1/16 in (1.6 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-25 (1/2-1) | 7.4 (290) | 28 | 430 | 6.7 (14.8) |
NOTES
Note |
---|
⁽¹⁾ CTWD (Contact Tip to Work Distance). Subtract 1/4 in (6.4 mm) to calculate Electrical Stickout. |
⁽²⁾ Procedures in these areas are procedures for short circuiting mode using 75% Argon, 25% CO2. NOTE: For 100% CO2 procedures, add 1 to 2 volts for short circuit transfer and 2 to 3 volts for globular transfer. |