SuperArc MIG wire, 33 lb. Plastic spool

Diameters / Packaging

Diameters

Pipeliner® 80S-G

MIG (GMAW)

CLASSIFICATIONS:
ER80S-G

Pipeliner® 80S-G from Lincoln Electric is the highest strength MIG wire in Pipeliner® family.

DETAILS

The highest strength MIG wire in the Pipeliner® family. Recommended for root pass welding of up to X100 grade pipe as well as hot, fill and cap pass welding of up to X80 grade pipe.

Features

  • Root pass capability up to X100 and hot, fill and cap pass up to X80 grade pipe
  • Microguard® Ultra provides superior feeding and arc stability
  • Impact toughness tested to -29°C (-20°F)
  • Q2 Lot® - Certificate showing actual deposit chemistry available online
  • ProTech® packaging system

Typical Applications

  • Root pass welding of up to X100 grade pipe
  • Hot, fill and cap pass welding of up to X80 grade pipe

Welding Positions

  • All

Shielding Gas

  • 100% CO2|Mixed Shielding Gas

Disclaimers

Warning -

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

You May Also Need

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

See test result disclaimer

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.28 ER80S-G

MECHANICAL PROPERTIES

Classification Shielding Gas Polarity Yield Strength @ 0.2% Offset
MPa (ksi)
Tensile Strength
MPa (ksi)
Elongation
%
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F)
Hardness Rockwell B
ER80S-G Requirement Not Specified DC+ 550 (80) min. Info. Only
Typical Result, As-welded 100% CO2 DC+ 630 (91) 700 (101) 25 70-87 (52-64) 97
Typical Result, As-welded 75% Ar, 25% CO2 DC+ 650 (94) 720 (104) 17 103-111 (76-82)
Typical Result, As-welded 80% Ar, 20% CO2 DC+ 610-650 (88-94) 690-730 (100-106) 23-26 73-183 (54-135)

DEPOSIT COMPOSITION

Classification Shielding Gas Polarity %C %Cr %Cu %Mn %Mo %Ni %P %S %Si
Typical Result 100% CO2 DC+ 0.09 0.05 0.18 1.39 0.40 0.04 0.008 0.006 0.40
Typical Result 75% Ar, 25% CO2 DC+ 0.10 0.05 0.17 1.42 0.45 0.01 0.01 0.48

WIRE COMPOSITION

Classification %Al %C %Cr %Mn %Mo %Ni %P %S %Si %Ti %V %Zr %Total Cu
ER80S-G Requirement 0.30 min. * 0.20 min. * 0.50 min. *
Typical Result 0.00 max. 0.09-0.10 0.02-0.03 1.73-1.81 0.45-0.47 0.01-0.02 0.006-0.008 0.003-0.009 0.61-0.64 0.01-0.03 0.00 max. 0.00 max. 0.15-0.28

TYPICAL OPERATING PROCEDURES

Diameter Polarity CTWD
mm (in.)⁽¹⁾
Wire Feed Speed
m/min (in/min)
Voltage
volts
Approx. Current
amps
Melt-off Rate
kg/hr (lb/hr)
1.1 mm (0.045 in) DC+ 12-19 (1/2-3/4) 3.2-12.7 (125-500) 19-30 145-340 1.5-6.0 (3.4-13.2)

NOTES

Note
* To meet the requirements of a "G" classification, the chemical composition of the eletrode must meet the minimum requirement for one or more of
⁽¹⁾ CTWD (Contact Tip to Work Distance). Subtract 1/4 in (6.4 mm) to calculate Electrical Stickout.