Diameters / Packaging
Diameters |
CAN 12.3 KG (3 x 4.1 KG, approx. 351 pcs) |
CAN 12.9 KG (3 x 4.3 KG, approx. 615 pcs) |
CAN 16.2 KG (3 x 5.4 KG, approx. 240 pcs) |
---|---|---|---|
2.5x350 mm | CH9B9-25-1 | ||
3.2x350 mm | CH9B9-32-1 | ||
4.0x450 mm | CH9B9-40-1 |
DETAILS
CHROMET 9-B9 are a low alloy, low hydrogen stick electrodes designed specifically for high integrity structural service at elevated temperature. Typically applications include main steam piping, oil refineries, coal liquefaction plants, power generation plants, and turbine castings.
Features
- B9 (P91) alloyed steel: Modified 9CrMo designed to weld equivalent "type 91" 9CrMo steels modified with small additions of niobium, vanadium and nitrogen for improved long term creep resistance
- Moisture resistant coatings giving very low weld metal hydrogen levels.
- Specifically designed for high integrity structural service at elevated temperature
- Weld metal chemistry is low in impurity elements allowing it to respect the X Factor (<15ppm) and J-factor (<120ppm)
Typical Applications
- Oil Refineries
- Coal Liquefaction and Gasification Plants
- Główne rurociągi pary
- Valves and Turbine Casings
- Power Generation Plants
Welding Positions
- All position, except vertical down
Service Information
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.5 | E9015-B91 H4 |
ISO | ISO 3580-B | E 6216-9C1MV |
MECHANICAL PROPERTIES
Classification |
Yield Strength @ 0.2% Offset
MPa (ksi) |
Tensile Strength
MPa (ksi) |
Elongation
% |
---|---|---|---|
E9015-B91 H4 Requirement | 530 (77) min. | 620 (90) min. | 17 min. |
E 6216-9C1MV Requirement | 530 (77) min. | 620 (90) min. | 15 min. |
Typical Result, Stress relieved | 590 (86) | 710 (103) | 22 |
DEPOSIT COMPOSITION
Classification | %Al | %C | %Cr | %Mn | %Mo | %N | %Nb | %Ni | %P | %S | %Si | %Total Cu | %V | %Mn+Ni |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
E9015-B91 H4 Requirement | 0.04 max. | 0.08 - 0.13 | 8.0 - 10.5 | 1.20 max. | 0.85 - 1.20 | 0.02 - 0.07 | 0.02 - 0.10 | 0.80 max. | 0.01 max. | 0.01 max. | 0.30 max. | 0.25 max. | 0.15 - 0.30 | 1.40 max. |
E 6216-9C1MV Requirement | 0.04 max. | 0.08 - 0.13 | 8.0 - 10.0 | 1.25 max. | 0.85 - 1.20 | 0.02 - 0.07 | 0.02 - 0.10 | 1.0 max. | 0.01 max. | 0.01 max. | 0.30 max. | 0.25 max. | 0.15 - 0.3 | 1.50 max. |
Typical Result | 0.01 | 0.10 | 9.0 | 0.55 | 1.00 | 0.05 | 0.04 | 0.30 | 0.01 | 0.01 | 0.25 | 0.05 | 0.20 | 0.85 |
TYPICAL OPERATING PROCEDURES
Diameter |
Current
Amps |
---|---|
2.5 mm (3/32") | 70-110 |
3.2 mm (1/8") | 80-140 |
4.0 mm (5/32") | 100-180 |
5.0 mm | 140-240 |