DETAILS
SECURTOP flash back arrestor devices offers a complete range compatible on regulators, torches, or simply on hoses. All installations must be equipped with flash back arrestor systems to guarantee you optimal security. All safety devices of the SECURTOP series are compact and meet the EN ISO 5175-1 standard.
Features
- Characteristics : 43 m3/h in Oxygene ; 8,5 m3/h in Acetylene at 1,5 bars
- Safety device compliant with EN ISO 5175-1; must be used on oxygen & fuel gas line close the regulator
- High pressure resistance : All SECURTOP 665 devices have passed hydraulic tests conducted at 100 bar.
- 2 functions safety devices : NV No return valve; FA Flame arrestor