Détails
Traits
- Combine with Lincolnweld® 888™ flux for H4 diffusible hydrogen weld deposits
- Charpy V-notch test results capable of exceeding 27 J (20 ft•lbf) @ -73°C (-100°F) with Lincolnweld® 888™ flux
- Excellent Tandem, AC and DC Operation
- Clean and easy slag removal minimizes risk of inclusions, even in narrow gap applications
Disclaimers
Des informations de service
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
DEPOSIT COMPOSITION
Flux | Classification | %B | %C | %Cr | %Cu | %Mn | %Mo | %Ni | %P | %S | %Si |
Diffusible Hydrogen
mL/100g Weld Metal |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lincolnweld® 888® | F11A10-ECG-G-H4 | 0.0018 | 0.10 | 0.39 | 0.05 | 1.47 | 0.44 | 2.72 | 0.001 | 0.006 | 0.30 | 2 |