Détails
An engineered alloy providing superior impact toughness at low temperatures.
Traits
- An engineered alloy providing superior impact toughness at low temperatures
- Microguard® Ultra provides superior feeding and arc stability
- ProTech® packaging system
Applications typiques
- Root pass welding
- Hot, fill and cap pass welding of up to X70 grade pipe
Positions de soudage
- All
Gaz de protection
- Mixed Shielding Gas|100% CO2
Disclaimers
Des informations de service
Vous pourriez également avoir besoin
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.18 | ER70S-6 |
ABS | ABS - Part 2 | 3YSA |
TUV | TUV ISO 14341-A | G 42 3 C1 3Si1, G 46 4 M21 3Si1, G 46 4 M31 3Si1 |
MECHANICAL PROPERTIES
Classification | Shielding Gas | Polarity |
Yield Strength @ 0.2% Offset
MPa (ksi) |
Tensile Strength
MPa (ksi) |
Elongation
% |
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F) |
---|---|---|---|---|---|---|
ER70S-6 Requirement | 100% CO2 | DC+ | 400 (58) min. | 480 (70) min. | 22 min. | 27 (20) min. |
Typical Result, As-welded | 100% CO2 | DC+ | 470 (68) | 580 (84) | 28 | 81-95 (60-70) |
WIRE COMPOSITION
Classification | %C | %Cr | %Mn | %Ni | %P | %S | %Si | %V | %Total Cu |
---|---|---|---|---|---|---|---|---|---|
ER70S-6 Requirement | 0.06 - 0.15 | 0.15 max. | 1.40 - 1.85 | 0.15 max. | 0.025 max. | 0.035 max. | 0.80 - 1.15 | 0.03 max. | 0.50 max. |
Typical Result | 0.10 | 0.03 | 1.46 | 0.01 | 0.005 | 0.009 | 0.82 | 0.003 max. | 0.17 |
TYPICAL OPERATING PROCEDURES
Diameter | Shielding Gas | Polarity |
CTWD
mm (in.)⁽¹⁾ |
Wire Feed Speed
m/min (in/min) |
Voltage
volts |
Approx. Current
amps |
Melt-off Rate
kg/hr (lb/hr) |
---|---|---|---|---|---|---|---|
1.0 mm (0.040 in) | 75-95% Ar / balance CO2 | DC+ | 12-19 (1/2-3/4) | 2.5-14.0 (100-550) | 19-31 | 105-320 | 1.0-5.2 (2.1-11.5) |
1.2 mm (0.047 in) | 75-95% Ar / balance CO2 | DC+ | 12-19 (1/2-3/4) | 3.2-12.7 (125-500) | 19-31 | 145-360 | 1.7-6.5 (3.7-14.3) |
NOTES
Note |
---|
⁽¹⁾ CTWD (Contact Tip to Work Distance). Subtract 1/4 in. (6.4 mm) to calculate Electrical Stickout. |