Détails
A PLW product which has been treated to minimize weld defects that can be seen in the use of MIG wires for the automaticTIG process.
Traits
- Q2 Lot® - certificate showing actual deposit composition and actual mechanical properties available online
- A PLW product which has been treated to minimize weld defects that can be seen in the use of MIG wires for the automatic TIG process
Applications typiques
- Nuclear power plant construction and maintenance
- Power and process industry related piping
- Medium to heavy mill scale base material
- Robotic or hard automation
Positions de soudage
- All
Gaz de protection
- 100% Argon
Disclaimers
Des informations de service
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.18 | ER70S-6 |
MECHANICAL PROPERTIES
Classification | Shielding Gas | Polarity |
Yield Strength @ 0.2% Offset
MPa (ksi) |
Tensile Strength
MPa (ksi) |
Elongation
% |
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F) |
---|---|---|---|---|---|---|
ER70S-6 Requirement | 100% Ar | DC- | 400 (58) min. | 480 (70) min. | 22 min. | 27 (20) min. |
Typical Result, As-welded | 100% Ar | DC- | 520 (75) | 620 (90) | 32 | 325-385 (240-284) |
WIRE COMPOSITION
Classification | %C | %Cr | %Mn | %Mo | %Ni | %P | %S | %Si | %V | %Total Cu |
---|---|---|---|---|---|---|---|---|---|---|
ER70S-6 Requirement | 0.06 - 0.15 | 0.15 max. | 1.40 - 1.85 | 0.15 max. | 0.15 max. | 0.025 max. | 0.035 max. | 0.80 - 1.15 | 0.03 max. | 0.50 max. |
Typical Result | 0.09 | 0.02 | 1.45 | 0.00 max. | 0.01 | 0.004 | 0.010 | 0.83 | 0.00 max. | 0.16 |