Our premium bare MIG wire, like our SuperArc® L-50, is an excellent choice for 50,000 psi (345 MPa) yield strength, carbon steel base materials.
Traits
- Deoxidizers tolerate light mill scale
- Microguard® Ultra provides superior feeding and arc stability
- Bare wire reduces copper fumes
- Supports short-circuiting, globular, axial spray and pulsed spray transfer
Applications typiques
- Clean to light mill scale base material
- Sheet metal to 380-485 MPa (55-70 ksi) yield strength material
- Pipeline
- Pressure vessels
- Structural steel
Positions de soudage
- All
Gaz de protection
- Mixed Shielding Gas|100% CO2
Disclaimers
Des informations de service
Vous pourriez également avoir besoin
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.18 | ER70S-3 |
CWB | CSA W48 | B-G 49A 2 C1 S3 (B-G 49A 2 C1 G3) |
MECHANICAL PROPERTIES
Classification | Shielding Gas | Polarity |
Yield Strength @ 0.2% Offset
MPa (ksi) |
Tensile Strength
MPa (ksi) |
Elongation
% |
Charpy V-Notch
J (ft-lbs) @ -20°C (0°F) |
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F) |
---|---|---|---|---|---|---|---|
ER70S-3 Requirement | 100% CO2 | DC+ | 400 (58) min. | 480 (70) min. | 22 min. | 27 (20) min. | |
Typical Result, As-welded | 100% CO2 | DC+ | 420 (61) | 510-540 (74-78) | 28 | 117-125 (86-92) | 72-121 (53-89) |
WIRE COMPOSITION
Classification | %Al | %C | %Cr | %Mn | %Mo | %Ni | %P | %S | %Si | %V | %Total Cu |
---|---|---|---|---|---|---|---|---|---|---|---|
ER70S-3 Requirement | 0.06 - 0.15 | 0.15 max. | 0.90 - 1.40 | 0.15 max. | 0.15 max. | 0.025 max. | 0.035 max. | 0.45 - 0.75 | 0.03 max. | ||
Typical Result | 0.00 max. | 0.07-0.08 | 0.02 | 1.17-1.26 | 0.01 max. | 0.01 | 0.006 | 0.009 | 0.51-0.60 | 0.00 max. | 0.02 |
TYPICAL OPERATING PROCEDURES
Diameter | Transfer Mode | Shielding Gas | Polarity |
CTWD
mm (in.)⁽¹⁾ |
Wire Feed Speed
m/min (in/min) |
Voltage
volts |
Approx. Current
amps |
Melt-off Rate
kg/hr (lb/hr) |
---|---|---|---|---|---|---|---|---|
0.035 in (0.9 mm) | Short Circuit Transfer ⁽²⁾ | 100% CO2 | DC+ | 9-12 (3/8-1/2) | 2.5 (100) | 18 | 80 | 0.7 (1.6) |
0.035 in (0.9 mm) | Short Circuit Transfer ⁽²⁾ | 100% CO2 | DC+ | 9-12 (3/8-1/2) | 3.8 (150) | 19 | 120 | 1.1 (2.4) |
0.035 in (0.9 mm) | Short Circuit Transfer ⁽²⁾ | 100% CO2 | DC+ | 9-12 (3/8-1/2) | 6.4 (250) | 22 | 175 | 1.8 (4.0) |
0.035 in (0.9 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-19 (1/2-3/4) | 9.5 (375 | 23 | 195 | 2.7 (6.0) |
0.035 in (0.9 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-19 (1/2-3/4) | 12.7 (500) | 29 | 230 | 3.6 (8.0) |
0.035 in (0.9 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-19 (1/2-3/4) | 15.2 (600) | 30 | 275 | 4.4 (9.6) |
0.045 in (1.1 mm) | Short Circuit Transfer ⁽²⁾ | 100% CO2 | DC+ | 12-19 (1/2-3/4) | 3.2 (125) | 19 | 145 | 1.5 (3.4) |
0.045 in (1.1 mm) | Short Circuit Transfer ⁽²⁾ | 100% CO2 | DC+ | 12-19 (1/2-3/4) | 3.8 (150) | 20 | 165 | 1.8 (4.0) |
0.045 in (1.1 mm) | Short Circuit Transfer ⁽²⁾ | 100% CO2 | DC+ | 12-19 (1/2-3/4) | 5.1 (200) | 21 | 200 | 2.4 (5.4) |
0.045 in (1.1 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-19 (1/2-3/4) | 8.9 (350) | 27 | 285 | 4.2 (9.2) |
0.045 in (1.1 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-19 (1/2-3/4) | 12.1 (475) | 30 | 335 | 5.7 (12.5) |
0.045 in (1.1 mm) | Spray Transfer | 90% Ar / 10% CO2 | DC+ | 12-19 (1/2-3/4) | 12.7 (500) | 30 | 340 | 6.0 (13.2) |
NOTES
Note |
---|
⁽¹⁾ CTWD (Contact Tip to Work Distance). Subtract 1/4 in. (6.4 mm) to calculate Electrical Stickout. |
⁽²⁾ Procedures in these areas are procedures for short circuiting mode using 100% CO2. When using 75% Argon, 25% CO2 for short circuit transfer, reduce voltage by 1 to 2 volts. |