Diameters / Packaging
Diameters |
|
---|---|
ED034895 |
DETAILS
For superior feeding and arc stability
Features
- Capable of producing welds with 690 MPa (100 ksi) tensile strength
- Suitable for use where consumables with less than 1% Ni are required
- Batch Managed Inventory
- Superior feeding and arc stability
Typical Applications
- NACE applications
- Oil tools
- Riser systems
- High-strength pipe
Welding Positions
- All
Shielding Gas
- Mixed Shielding Gas|100% CO2
Service Information
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.28 | ER100S-G |
MECHANICAL PROPERTIES
Classification | Shielding Gas | Polarity |
Yield Strength @ 0.2% Offset
MPa (ksi) |
Tensile Strength
MPa (ksi) |
Elongation
% |
Charpy V-Notch
J (ft-lbs) @ -50°C (-60°F) |
Hardness Rockwell B |
---|---|---|---|---|---|---|---|
ER100S-G Requirement | Not Specified | DC+ | 690 (100) min. | Info. Only | |||
Typical Result, As-welded | 90% Ar, 10% CO2 | DC+ | 660-690 (96-100) | 760-790 (110-115) | 20-22 | 45-70 (34-52) | 99 |
DEPOSIT COMPOSITION
Classification | Shielding Gas | Polarity | %Al | %C | %Cr | %Cu | %Mn | %Mo | %Ni | %P | %S | %Si | %Ti | %V | %Zr |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Typical Result | 90% Ar, 10% CO2 | DC+ | 0.00 max. | 0.11-0.12 | 0.26-0.37 | 0.18-0.23 | 1.12-1.23 | 0.42-0.47 | 0.89-1.06 | 0.006-0.008 | 0.001-0.006 | 0.41-0.45 | 0.001 max. | 0.005 max. | 0.001 max. |
WIRE COMPOSITION
Classification | %Al | %C | %Cr | %Mn | %Mo | %Ni | %P | %S | %Si | %Ti | %V | %Zr | %Total Cu |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ER100S-G Requirement | 0.30 min. * | 0.20 min. * | 0.50 min. * | ||||||||||
Typical Result | 0.00 max. | 0.10-0.12 | 0.27-0.34 | 1.52-1.55 | 0.42-0.47 | 0.87-0.96 | 0.007-0.010 | 0.001-0.006 | 0.57-0.62 | 0.00 max. | 0.005 max. | 0.001 max. | 0.20-0.25 |
NOTES
Note |
---|
* To meet the requirements of a "G" classification, the chemical composition of the electrode must meet the minimum requirement for one or more of these elements. |