DETAILS
Low Alloy Solid Electrode • AWS EB2R
Features
- B2 alloyed steel: 1.25% chromium, 0.5% molybdenum deposit which meets specific requirements for improved temper embrittlement resistance with prolonged service at 400°C-600°C (752°F-1112°F)
- Excellent corrosion resistance in refineries to sulfur bearing crude oil at 250°C-450°C (482°F-842°F)
- Actual (Type 3.1) Certificates containing chemical composition for each lot of wire are available in the Lincoln Electric Certificate Center
Disclaimers
Service Information
Documentation
You May Also Need
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.23 | EB2R |
ISO | ISO 24598-A | S S CrMo1 |
WIRE COMPOSITION
Classification | %As | %C | %Cr | %Mn | %Mo | %P | %S | %Sb | %Si | %Sn | %Total Cu |
---|---|---|---|---|---|---|---|---|---|---|---|
EB2R Requirement | 0.005 max. | 0.07 - 0.15 | 1.00 - 1.75 | 0.45 - 1.00 | 0.45 - 0.65 | 0.010 max. | 0.010 max. | 0.005 max. | 0.05 - 0.30 | 0.005 max. | 0.15 max. |
S S CrMo1 Requirement | 0.08 - 0.15 | 0.90 - 1.30 | 0.60 - 1.00 | 0.40 - 0.65 | 0.020 max. | 0.020 max. | 0.05 - 0.25 | ||||
Typical Result | 0.001 | 0.13 | 1.15 | 0.81 | 0.52 | 0.005 | 0.006 | 0.001 max. | 0.10 | 0.001 max. | 0.07 |