DETAILS
Designed for high strength, low-alloy applications using 100% CO2. These electrodes exhibit robust impact properties, even with a notch offset of 2.5 mm from weld centerline, as well as superior crack resistance, due to low diffusible hydrogen levels (4mL/100 grams of weld deposit max).
Features
- Capable of producing weld deposits with impact toughness exceeding 88 - 123 J (65 - 91 ft·lbf) at -40°C (-40°F)
- Designed for welding with 100% CO2 shielding gas
- Premium arc performance and bead appearance
- Meets AWS D1.8 seismic lot waiver requirements
- ProTech® foil bag packaging
- Notes: AWS D1.8 structural steel seismic supplement test data can be found at the Lincoln Electric Certificate Center.
Disclaimers
Service Information
Documentation
You May Also Need
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.29 | E81T1-Ni1C-JH4 |
AWS | AWS A5.36 | E81T1-C1A4-Ni1-H4 |
ABS | ABS - Part 2 | 4YQ460SA H5 |
CWB | CSA W48 | E551T1-C1A4-Ni1-H4 (E551T1-Ni1C-JH4) |
DNV-GL | DNV - 2.9 | IV Y46MS H5 |
LR | LR - Chapter 11 | 4Y46S H5 |
MECHANICAL PROPERTIES
Classification | Shielding Gas | Polarity |
Yield Strength @ 0.2% Offset
MPa (ksi) |
Tensile Strength
MPa (ksi) |
Elongation
% |
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F) |
Charpy V-Notch
J (ft-lbs) @ -40°C (-40°F) |
---|---|---|---|---|---|---|---|
E81T1-Ni1C-JH4 Requirement | 100% CO2 | DC+ | 470 (68) min. | 550-690 (80-100) | 19 min. | 27 (20) min. | |
E81T1-C1A4-Ni1-H4 Requirement | 100% CO2 | DC+ | 470 (68) min. | 550-690 (80-100) | 19 min. | 27 (20) min. | |
Typical Result, As-welded | 100% CO2 | DC+ | 510 (74) | 570-640 (83-92) | 22 | 85-150 (63-111) | 47-153 (35-113) |
DEPOSIT COMPOSITION
Classification | Shielding Gas | Polarity | %B | %C | %Cr | %Mn | %Mo | %Ni | %P | %S | %Si | %V |
Diffusible Hydrogen
mL/100g Weld Metal |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
E81T1-Ni1C-JH4 Requirement | 100% CO2 | DC+ | 0.12 max. | 0.15 max. | 1.50 max. | 0.35 max. | 0.80 - 1.10 | 0.030 max. | 0.030 max. | 0.80 max. | 0.05 max. | 4.0 max. | |
E81T1-C1A4-Ni1-H4 Requirement | 100% CO2 | DC+ | 0.12 max. | 0.15 max. | 1.75 max. | 0.35 max. | 0.80 - 1.10 | 0.030 max. | 0.030 max. | 0.80 max. | 0.05 max. | 4 max. | |
Typical Result | 100% CO2 | DC+ | 0.0050-0.006 | 0.04-0.05 | 0.04-0.06 | 1.12-1.42 | 0.01 | 0.81-1.00 | 0.012 max. | 0.010 max. | 0.24-0.35 | 0.02-0.03 | 1.7-3.2 |
TYPICAL OPERATING PROCEDURES
Diameter | Shielding Gas | Polarity |
CTWD
mm (in.)⁽¹⁾ |
Wire Feed Speed
m/min (in/min) |
Voltage
volts |
Approx. Current
amps |
Melt-off Rate
kg/hr (lb/hr) |
Deposition Rate
kg/hr (lb/hr) |
Efficiency
% |
---|---|---|---|---|---|---|---|---|---|
0.045 in (1.1 mm) | 100% CO2 | DC+ | 25 (1) | 4.4 (175) | 23-28 | 140 | 1.8 (4.0) | 1.6 (3.5) | 86-88 |
0.045 in (1.1 mm) | 100% CO2 | DC+ | 25 (1) | 5.1 (200) | 24-29 | 150 | 2.1 (4.6) | 1.8 (4.0) | 86-88 |
0.045 in (1.1 mm) | 100% CO2 | DC+ | 25 (1) | 6.4 (250) | 25-30 | 165 | 2.6 (5.7) | 2.3 (5.0) | 86-88 |
0.045 in (1.1 mm) | 100% CO2 | DC+ | 25 (1) | 7.6 (300) | 25-30 | 190 | 3.1 (6.8) | 2.7 (6.0) | 86-88 |
0.045 in (1.1 mm) | 100% CO2 | DC+ | 25 (1) | 8.9 (350) | 26-31 | 205 | 3.6 (8.0) | 3.2 (7.0) | 86-88 |
0.045 in (1.1 mm) | 100% CO2 | DC+ | 25 (1) | 9.5 (375) | 26-31 | 225 | 3.9 (8.6) | 3.4 (7.5) | 86-88 |
0.045 in (1.1 mm) | 100% CO2 | DC+ | 25 (1) | 10.8 (425) | 27-32 | 245 | 4.4 (9.7) | 3.8 (8.5) | 86-88 |
0.045 in (1.1 mm) | 100% CO2 | DC+ | 25 (1) | 12.1 (475) | 28-33 | 265 | 4.9 (10.8) | 4.3 (9.5) | 86-88 |
0.045 in (1.1 mm) | 100% CO2 | DC+ | 25 (1) | 12.7 (500) | 29-34 | 275 | 5.2 (11.4) | 4.5 (10.0) | 86-88 |
0.052 in (1.3 mm) | 100% CO2 | DC+ | 25 (1) | 3.8 (150) | 23-28 | 150 | 2.0 (4.5) | 1.8 (3.9) | 86-88 |
0.052 in (1.3 mm) | 100% CO2 | DC+ | 25 (1) | 4.7 (185) | 24-29 | 165 | 2.5 (5.5) | 2.2 (4.8) | 86-88 |
0.052 in (1.3 mm) | 100% CO2 | DC+ | 25 (1) | 5.7 (225) | 24-29 | 190 | 3.1 (6.7) | 2.7 (5.9) | 86-88 |
0.052 in (1.3 mm) | 100% CO2 | DC+ | 25 (1) | 6.4 (250) | 25-30 | 215 | 3.4 (7.5) | 2.9 (6.5) | 86-88 |
0.052 in (1.3 mm) | 100% CO2 | DC+ | 25 (1) | 7.0 (275) | 25-30 | 235 | 3.7 (8.2) | 3.2 (7.2) | 86-88 |
0.052 in (1.3 mm) | 100% CO2 | DC+ | 25 (1) | 7.6 (300) | 26-31 | 255 | 4.1 (9.0) | 3.5 (7.8) | 86-88 |
0.052 in (1.3 mm) | 100% CO2 | DC+ | 25 (1) | 8.5 (335) | 26-31 | 275 | 4.5 (10.0) | 4.0 (8.7) | 86-88 |
0.052 in (1.3 mm) | 100% CO2 | DC+ | 25 (1) | 9.5 (375) | 27-32 | 295 | 5.1 (11.2) | 4.4 (9.8) | 86-88 |
0.052 in (1.3 mm) | 100% CO2 | DC+ | 25 (1) | 10.2 (400) | 27-34 | 310 | 5.4 (12.0) | 4.7 (10.4) | 86-88 |
1/16 in (1.6 mm) | 100% CO2 | DC+ | 25 (1) | 3.8 (150) | 24-29 | 200 | 2.9 (6.3) | 2.5 (5.5) | 86-88 |
1/16 in (1.6 mm) | 100% CO2 | DC+ | 25 (1) | 4.4 (175) | 24-30 | 210 | 3.3 (7.4) | 2.9 (6.4) | 86-88 |
1/16 in (1.6 mm) | 100% CO2 | DC+ | 25 (1) | 5.1 (200) | 25-30 | 235 | 3.8 (8.4) | 3.3 (7.3) | 86-88 |
1/16 in (1.6 mm) | 100% CO2 | DC+ | 25 (1) | 5.7 (225) | 25-31 | 265 | 4.3 (9.5) | 3.7 (8.2) | 86-88 |
1/16 in (1.6 mm) | 100% CO2 | DC+ | 25 (1) | 6.4 (250) | 26-31 | 285 | 4.8 (10.5) | 4.2 (9.2) | 86-88 |
1/16 in (1.6 mm) | 100% CO2 | DC+ | 25 (1) | 7.0 (275) | 26-32 | 305 | 5.3 (11.6) | 4.6 (10.1) | 86-88 |
1/16 in (1.6 mm) | 100% CO2 | DC+ | 25 (1) | 8.3 (325) | 27-32 | 335 | 6.2 (13.7) | 5.4 (11.9) | 86-88 |
1/16 in (1.6 mm) | 100% CO2 | DC+ | 25 (1) | 8.9 (350) | 28-34 | 365 | 6.7 (14.7) | 5.8 (12.8) | 86-88 |
NOTES
Note |
---|
⁽¹⁾ To estimate ESO, subtract 1/4 in. (6.0 mm) from CTWD. |
NOTE 1: FEMA and AWS D1.8 structural steel seismic supplement test data can be found on this product at www.lincolnelectric.com. |
NOTE 2: This product contains micro-alloying elements. Additional information available upon request. |