DETAILS
LincoreĀ® 420 Metal-Cored Submerged Arc Wire is recommended to be used with primary 801 and secondary 802 standard flux. Composition and properties depend upon dilution. Single layer deposit properties depend upon base metal and/or build-up material.
Features
- Metal-cored wire that is most widely used for caster roll rebuilding
Service Information
You May Also Need
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
MECHANICAL PROPERTIES
Flux | Classification | Hardness Rockwell C |
---|---|---|
Lincolnweld® 801® | Typical Result | 46-50 |
DEPOSIT COMPOSITION
Flux | Classification | %C | %Cr | %Mn | %Si |
---|---|---|---|---|---|
Lincolnweld® 801® | Typical Result | 0.20 | 12.0 | 1.2 | 0.5 |
TYPICAL OPERATING PROCEDURES
Diameter | Polarity |
Wire Feed Speed
m/min (in/min) |
Voltage
volts |
Approx. Current
amps |
---|---|---|---|---|
3/32 in (2.4 mm) | DC+ | 1.7 (65) | 24 | 250 |
3/32 in (2.4 mm) | DC+ | 3.0 (120) | 28 | 375 |
3/32 in (2.4 mm) | DC+ | 4.4 (175) | 31 | 450 |
1/8 in (3.2 mm) | DC+ | 1.5 (60) | 26 | 350 |
1/8 in (3.2 mm) | DC+ | 2.5 (100) | 28 | 500 |
1/8 in (3.2 mm) | DC+ | 3.6 (140) | 30 | 625 |
5/32 in (4.0 mm) | DC+ | 1.4 (55) | 27 | 475 |
5/32 in (4.0 mm) | DC+ | 2.2 (85) | 30 | 650 |