DÉTAILS
Electrode enrobée en acier doux standard pour la passe de racine dans l’industrie des tubes.
Caractéristiques
- Pénétration excellente
- Electrode cellulosique
- Excellente soudabilité en verticale et au plafond.
Exemples d'applications
- Cross country and in-plant pipe welding
- Excellente en passes de racine
- Soudage sur aciers galvanisés et à revêtement spécial
- Welding on galvanized and specially coated steels
Positions de soudage
- Toutes positions
Gaz de protection
- Non applicable
Service d'information
Documentation
Vous pourriez avoir également besoin de
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. Page de recherche SDS
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.1 | E6010 |
ISO | ISO 2560-A | E 42 3 C 2 5 |
ABS | AWS A5.1 | E6010 |
CWB | CSA W48 | E4310 |
DNV-GL | DNV - 2.9 | 3 |
MECHANICAL PROPERTIES
Classification |
Yield Strength @ 0.2% Offset
MPa (ksi) |
Tensile Strength
MPa (ksi) |
Elongation
% |
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F) |
Hardness Rockwell B |
---|---|---|---|---|---|
E6010 Requirement | 330 (48) min. | 410 (60) min. | 22 min. | 27 (20) min. | |
Typical Result, As-welded | 430-480 (62-69) | 530-580 (76-85) | 23-31 | 51-122 (38-90) | 82-91 |
DEPOSIT COMPOSITION
Classification | %C | %Cr | %Mn | %Mo | %Ni | %P | %S | %Si | %V |
---|---|---|---|---|---|---|---|---|---|
E6010 Requirement | 0.20 max. | 0.20 max. | 1.20 max. | 0.30 max. | 0.30 max. | 1.00 max. | 0.08 max. | ||
Typical Result | 0.12-0.16 | 0.06 max. | 0.50-0.67 | 0.02 | 0.07 max. | 0.007-0.012 | 0.004-0.011 | 0.14-0.25 | 0.01 |
TYPICAL OPERATING PROCEDURES
Diameter | Polarity⁽¹⁾ |
Current
Amps |
---|---|---|
3/32 in (2.4 mm) | DC+ | 50-85 |
3/32 in (2.4 mm) | DC- | 50-85 |
1/8 in (3.2 mm) | DC+ | 75-135 |
1/8 in (3.2 mm) | DC- | 75-135 |
5/32 in (4.0 mm) | DC+ | 100-175 |
5/32 in (4.0 mm) | DC- | 100-175 |
3/16 in (4.8 mm) | DC+ | 140-225 |
3/16 in (4.8 mm) | DC- | – |
NOTES
Note |
---|
⁽¹⁾ Preferred polarity is listed first. |