Diámetros / Embalaje
Diámetros mm |
55 lb Spool |
---|---|
1/8 in (3.2 mm) | ED035188 |
Detalles
LINCOLNWELD® 410NiMo is used to overlay mild and low alloy steels, a preheat and inter-pass temperature of 300°F (150°C) or greater are recommended during welding. Additionally post-weld heat treatment should not exceed 1150°F (620°C) as higher temperatures may result in hardening.
Características
- Used to overlay mild and low alloy steels
- Preheat and inter-pass temperatures of 300°F (150°C) or greater are recommended during welding
- Post-weld heat treatment should not exceed 1150°F (620° C) as higher temperatures may result in hardening
- Q2 Lot® - Certificates showing actual wire chemistry available online
Servicio de información
ANTES DE USARLO, LEA Y COMPRENDA LA HOJA DE DATOS DE SEGURIDAD (SDS) DE ESTE PRODUCTO Y LA INFORMACIÓN ESPECÍFICA IMPRESA EN EL ENVASE DEL PRODUCTO. Página de Búsqueda SDS
Ver los resultados de la prueba de limitación de responsabilidad
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.9 | ER410NiMo |
WIRE COMPOSITION
Classification | %C | %Cr | %Cu | %Mn | %Mo | %N | %Nb | %Ni | %P | %S | %Si |
---|---|---|---|---|---|---|---|---|---|---|---|
ER410NiMo Requirement | 0.06 max. | 11.0 - 12.5 | 0.75 max. | 0.6 max. | 0.4 - 0.7 | Info. Only | Info. Only | 4.0 - 5.0 | 0.03 max. | 0.03 max. | 0.5 max. |
Typical Result | 0.02-0.03 | 11.8-12.1 | 0.04-0.06 | 0.4-0.5 | 0.5-0.6 | 0.02-0.05 | 0.00 max. | 4.5-4.7 | 0.01-0.02 | 0.01 max. | 0.4 |
TYPICAL OPERATING PROCEDURES
Diameter |
Voltage
volts |
Approx. Current
amps |
Flux |
---|---|---|---|
1/8 in (3.2 mm) | 29-32 | 350-450 | Lincolnweld® P2000™ |