SuperArc MIG wire, fiber spool

Diámetros / Embalaje

Diámetros
mm
33 lb Spool
44 lb Spool
60 lb Spool
500 lb Accu-Pak® Box
500 lb Accu-Trak® Drum
500 LB DRUM
500 lb Infinity-Pak®
1000 lb Accu-Pak® Box
1000 lb Accu-Trak® Drum
1000 lb Infinity-Pak
1000 lb Precise-Trak® Reel
0.035 in (0.9 mm) ED032924 ED021268 ED021269 ED021052 ED028825 ED032379
0.045 IN ED561201
0.045 in (1.1 mm) ED031409,ED032925 ED031915 ED032901 ED020526 ED034535 ED032844 ED028826 ED031930
0.052 in (1.3 mm) ED031916 ED020527 ED032845 ED029082
1/16 in (1.6 mm) ED027274 ED032846

SuperArc® L-50®

Soldadura de Arco Metálico con Gas (GMAW) | ED021269

CLASIFICACIONES:
ER70S-3

SuperArc L-50 brinda niveles moderados de manganeso y silicio para desoxidación de superficies de limpieza, hasta con ligera escamación, alimentación y estabilidad de arco superiores.

Detalles

Our most popular MIG wire, SuperArc® L-50®, premium copper coated wire, is an excellent choice for 50,000 psi (345 MPa) yield strength, carbon steel base materials.

Características

  • Moderate levels of manganese and silicon for deoxidization of clean to light mill scale surfaces
  • Superior feeding and arc stability
  • Copper coated for long contact tip life
  • Supports short-circuiting, globular, axial spray and pulsed spray transfer

También puede necesitar

ANTES DE USARLO, LEA Y COMPRENDA LA HOJA DE DATOS DE SEGURIDAD (SDS) DE ESTE PRODUCTO Y LA INFORMACIÓN ESPECÍFICA IMPRESA EN EL ENVASE DEL PRODUCTO. Página de Búsqueda SDS

Ver los resultados de la prueba de limitación de responsabilidad

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.18 ER70S-3
ABS ABS - Part 2 3YSA H5
CWB CSA W48 B-G 49A 3 C1 S3 (B-G 49A 3 C1 G3)
DNV-GL DNV - 2.9 III YMS H5
LR LR - Chapter 11 3YS H5
MIL MIL-E-23765/1D MIL-70S-3
MIL MIL-E-23765/1E MIL-70S-3

MECHANICAL PROPERTIES

Classification Shielding Gas Polarity Yield Strength @ 0.2% Offset
MPa (ksi)
Tensile Strength
MPa (ksi)
Elongation
%
Charpy V-Notch
J (ft-lbs) @ -20°C (0°F)
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F)
Typical Result, As-welded 100% CO2 DC+ 400 (58) 500-560 (73-81) 24 95-132 (70-98) 95-106 (70-78)

WIRE COMPOSITION

Classification %C %Cr %Mn %Mo %Ni %P %S %Si %Total Cu %V
ER70S-3 Requirement 0.06 - 0.15 0.15 max. 0.90 - 1.40 0.15 max. 0.15 max. 0.025 max. 0.035 max. 0.45 - 0.75 0.50 max. 0.03 max.
Typical Result 0.06-0.11 0.02-0.04 1.15-1.24 0.02 max. 0.01-0.04 0.004-0.012 0.004-0.011 0.44-0.62 0.00 max. 0.12-0.27

TYPICAL OPERATING PROCEDURES

Diameter Transfer Mode Shielding Gas Polarity CTWD
mm (in.)⁽¹⁾
Wire Feed Speed
m/min (in/min)
Voltage
volts
Approx. Current
amps
Melt-off Rate
kg/hr (lb/hr)
0.030 in (0.8 mm) Short Circuit Transfer 100% CO2 DC+ 9-12 (3/8-1/2) 1.9 (75) 17 35 0.4 (0.9)
0.030 in (0.8 mm) Short Circuit Transfer 100% CO2 DC+ 9-12 (3/8-1/2) 3.8 (150) 18 70 0.8 (1.8)
0.030 in (0.8 mm) Short Circuit Transfer 100% CO2 DC+ 9-12 (3/8-1/2) 7.6 (300) 22 130 1.6 (3.6)
0.035 in (0.9 mm) Short Circuit Transfer ⁽²⁾ 100% CO2 DC+ 9-12 (3/8-1/2) 2.5 (100) 18 80 0.7 (1.6)
0.035 in (0.9 mm) Short Circuit Transfer ⁽²⁾ 100% CO2 DC+ 9-12 (3/8-1/2) 3.8 (150) 19 120 1.1 (2.4)
0.035 in (0.9 mm) Short Circuit Transfer ⁽²⁾ 100% CO2 DC+ 9-12 (3/8-1/2) 6.4 (250) 22 175 1.8 (4.0)
0.035 in (0.9 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 9.5 (375) 23 195 2.7 (6.0)
0.035 in (0.9 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 12.7 (500) 29 230 3.6 (8.0)
0.035 in (0.9 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 15.2 (600) 30 275 4.4 (9.6)
0.045 in (1.1 mm) Short Circuit Transfer ⁽²⁾ 100% CO2 DC+ 12-19 (1/2-3/4) 3.2 (125) 19 145 1.5 (3.4)
0.045 in (1.1 mm) Short Circuit Transfer ⁽²⁾ 100% CO2 DC+ 12-19 (1/2-3/4) 3.8 (150) 20 165 1.8 (4.0)
0.045 in (1.1 mm) Short Circuit Transfer ⁽²⁾ 100% CO2 DC+ 12-19 (1/2-3/4) 5.1 (200) 21 200 2.4 (5.4)
0.045 in (1.1 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 8.9 (350) 27 285 4.2 (9.2)
0.045 in (1.1 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 12.1 (475) 30 335 5.7 (12.5)
0.045 in (1.1 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 12.7 (500) 30 340 6.0 (13.2)
0.052 in (1.3 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 7.6 (300) 30 300 4.8 (10.6)
0.052 in (1.3 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 8.1 (320) 30 320 5.2 (11.5)
0.052 in (1.3 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 12.3 (485) 32 430 7.8 (17.1)
1/16 in (1.6 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-25 (1/2-1) 5.3 (210) 25 325 4.8 (10.7)
1/16 in (1.6 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-25 (1/2-1) 6.0 (235) 27 350 5.4 (12.0)
1/16 in (1.6 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-25 (1/2-1) 7.4 (290) 28 430 6.7 (14.8)

NOTES

Note
⁽¹⁾ CTWD (Contact Tip to Work Distance). Subtract 1/4 in (6.4 mm) to calculate Electrical Stickout
⁽²⁾ Procedures in these areas are procedures for short circuiting mode using 100% CO2. When using 75% Argon, 25% CO2 for short circuit transfer, reduce voltage by 1 to 2 volts.