UltraCore, 50 LB coil

Diameters / Packaging

Diameters
50 lb Coil Buy America
3/32 in (2.4 mm) ED032940

UltraCore® 75C Flux-cored (FCAW-G) Wire

Flux-Cored Gas-Shielded (FCAW-G) | ED032940

CLASSIFICATIONS:
E70T-5C-JH4
E70T5-C1A4-CS1-H4

UltraCore® 75C is capable of producing low diffusible hydrogen levels and high deposition rates.

DETAILS

UltraCore® 75C is a gas-shielded flux-cored wire capable of producing low diffusible hydrogen levels and high deposition rates. It is recommended for both single or multiple pass welding in either semi-automatic or automatic applications.

Features

  • High deposition in the flat and horizontal positions
  • H4 diffusible hydrogen levels
  • Designed for welding with 100% CO2 shielding gas
  • Premium arc performance and bead appearance
  • ProTech® foil bag packaging
  • This product is manufactured with steel made and melted in the U.S.A. It complies to Buy America (BA), Buy American (BAA), Build America, Buy America (BABA), and American Iron & Steel (AIS) standards.

Service Information

You May Also Need

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.20 E70T-5C-JH4
AWS AWS A5.36 E70T5-C1A4-CS1-H4
CWB CSA W48 E490T5-C1A4-CS1-H4 (E492T-5J-H4)

MECHANICAL PROPERTIES

Classification Shielding Gas Polarity Yield Strength @ 0.2% Offset
MPa (ksi)
Tensile Strength
MPa (ksi)
Elongation
%
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F)
Charpy V-Notch
J (ft-lbs) @ -40°C (-40°F)
E70T-5C-JH4 Requirement 100% CO2 DC+ 400 (58) min. 480-660 (70-95) 22 min. 27 (20) min.
E70T5-C1A4-CS1-H4 Requirement 100% CO2 DC+ or DC- 400 (58) min. 480-660 (70-95) 22 min. 27 (20) min.
Typical Result, As-welded 100% CO2 DC+ 440 (64) 540-590 (78-85) 26 75-172 (55-127) 28-173 (21-128)

DEPOSIT COMPOSITION

Classification Shielding Gas Polarity %C %Mn %P %S %Si Diffusible Hydrogen
mL/100g Weld Metal
E70T-5C-JH4 Requirement 100% CO2 DC+ 0.12 max. 1.75 max. 0.03 max. 0.03 max. 0.90 max. 4.0 max.
E70T5-C1A4-CS1-H4 Requirement 100% CO2 DC+ or DC- 0.12 max. 1.75 max. 0.030 max. 0.030 max. 0.90 max. 4 max.
Typical Result 100% CO2 DC+ 0.05-0.08 1.44-1.75 0.016 max. 0.012 max. 0.40-0.60 2-4

TYPICAL OPERATING PROCEDURES

Diameter Shielding Gas Polarity CTWD
mm (in.)⁽¹⁾
Wire Feed Speed
m/min (in/min)
Voltage
volts
Approx. Current
amps
Melt-off Rate
kg/hr (lb/hr)
Deposition Rate
kg/hr (lb/hr)
Efficiency
%
1/16 in (1.6 mm) 100% CO2 DC+ 19-25 (3/4-1) 5.1 (200) 29-34 230 4.0 (8.7) 3.1 (6.9) 76-86
1/16 in (1.6 mm) 100% CO2 DC+ 19-25 (3/4-1) 6.4 (250) 31-36 270 5.0 (11.0) 3.8 (8.5) 76-86
1/16 in (1.6 mm) 100% CO2 DC+ 19-25 (3/4-1) 7.6 (300) 32-37 295 5.9 (13.1) 4.5 (10.0) 76-86
1/16 in (1.6 mm) 100% CO2 DC+ 19-25 (3/4-1) 8.9 (350) 33-38 335 6.9 (15.2) 5.5 (12.1) 76-86
1/16 in (1.6 mm) 100% CO2 DC+ 19-25 (3/4-1) 10.2 (400) 33-38 360 7.9 (17.4) 6.3 (13.9) 76-86
1/16 in (1.6 mm) 100% CO2 DC+ 19-25 (3/4-1) 12.7 (500) 35-40 415 9.9 (21.8) 7.9 (17.5) 76-86
5/64 in (2.0 mm) 100% CO2 DC+ 25-32 (1-1 1/4) 5.1 (200) 29-34 295 5.7 (12.7) 4.8 (10.5) 82-86
5/64 in (2.0 mm) 100% CO2 DC+ 25-32 (1-1 1/4) 6.4 (250) 30-35 345 7.2 (15.9) 6.0 (13.2) 82-86
5/64 in (2.0 mm) 100% CO2 DC+ 25-32 (1-1 1/4) 7.6 (300) 32-37 390 8.6 (19.0) 7.1 (15.6) 82-86
5/64 in (2.0 mm) 100% CO2 DC+ 25-32 (1-1 1/4) 8.9 (350) 33-38 425 10.1 (22.3) 8.5 (18.7) 82-86
5/64 in (2.0 mm) 100% CO2 DC+ 25-32 (1-1 1/4) 10.2 (400) 34-39 465 11.5 (25.3) 9.9 (21.8) 82-86
3/32 in (2.4 mm) 100% CO2 DC+ 32 (1-3/8) 3.2 (125) 23-28 335 5.5 (12.2) 4.8 (10.7) 87-90
3/32 in (2.4 mm) 100% CO2 DC+ 32 (1-3/8) 5.1 (200) 27-32 445 8.8 (19.3) 7.6 (16.7) 87-90
3/32 in (2.4 mm) 100% CO2 DC+ 32 (1-3/8) 6.4 (250) 29-34 500 10.9 (24.1) 9.6 (21.3) 87-90
3/32 in (2.4 mm) 100% CO2 DC+ 32 (1-3/8) 7.6 (300) 31-36 590 13.2 (29.2) 11.8 (26.0) 87-90
3/32 in (2.4 mm) 100% CO2 DC+ 32 (1-3/8) 8.3 (325) 32-37 605 14.2 (31.4) 12.8 (28.3) 87-90

NOTES

Note
⁽¹⁾ To estimate ESO, subtract 1/4 in. (6.0 mm) from CTWD.