DETAILS
One of Lincoln's premium copper coated MIG wires, SuperArc® G4Si1 is an excellent choice for a US manufactured solid wire meeting the requirements of the G4Si1 conformance of the EN ISO specification.
Typical Applications
- Automotive
Welding Positions
- All
Shielding Gas
- 100% CO | 85-90% Argon / Balance CO | Flow Rate: 30-50 CFH
Disclaimers
Service Information
Documentation
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.18 | ER70S-6 |
MECHANICAL PROPERTIES
Classification | Shielding Gas | Polarity |
Yield Strength @ 0.2% Offset
MPa (ksi) |
Tensile Strength
MPa (ksi) |
Elongation
% |
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F) |
---|---|---|---|---|---|---|
ER70S-6 Requirement | 100% CO2 | DC+ | 400 (58) min. | 480 (70) min. | 22 min. | 27 (20) min. |
Typical Result, As-welded | 100% CO2 | DC+ | 470 (68) | 590-600 (85-87) | 24 | 50-100 (37-74) |
WIRE COMPOSITION
Classification | %C | %Cr | %Mn | %Mo | %Ni | %P | %S | %Si | %Total Cu |
---|---|---|---|---|---|---|---|---|---|
ER70S-6 Requirement | 0.06 - 0.15 | 0.15 max. | 1.40 - 1.85 | 0.15 max. | 0.15 max. | 0.025 max. | 0.035 max. | 0.80 - 1.15 | 0.50 max. |
Typical Result | 0.09 | 0.02 | 1.67 | 0.00 max. | 0.02 | 0.005 | 0.006-0.007 | 0.87 | 0.20 |
TYPICAL OPERATING PROCEDURES
Diameter | Transfer Mode | Shielding Gas | Polarity |
CTWD
mm (in.)⁽¹⁾ |
Wire Feed Speed
m/min (in/min) |
Voltage
volts |
Approx. Current
amps |
Melt-off Rate
kg/hr (lb/hr) |
---|---|---|---|---|---|---|---|---|
0.045 in (1.1 mm) | Short Circuit Transfer ⁽²⁾ | 100% CO2 | DC+ | 12-19 (1/2-3/4) | 3.2 (125) | 19 | 145 | 1.5 (3.4) |
0.045 in (1.1 mm) | Short Circuit Transfer ⁽²⁾ | 100% CO2 | DC+ | 12-19 (1/2-3/4) | 3.8 (150) | 20 | 165 | 1.8 (4.0) |
0.045 in (1.1 mm) | Short Circuit Transfer ⁽²⁾ | 100% CO2 | DC+ | 12-19 (1/2-3/4) | 5.1 (200) | 21 | 200 | 2.5 (5.4) |
0.045 in (1.1 mm) | Spray Transfer | 85% Ar / 15% CO2 | DC+ | 12-19 (1/2-3/4) | 8.9 (350) | 27 | 285 | 4.2 (9.2) |
0.045 in (1.1 mm) | Spray Transfer | 85% Ar / 15% CO2 | DC+ | 12-19 (1/2-3/4) | 12.1 (475) | 30 | 335 | 5.7 (12.5) |
0.045 in (1.1 mm) | Spray Transfer | 85% Ar / 15% CO2 | DC+ | 12-19 (1/2-3/4) | 12.7 (500) | 30 | 340 | 6.0 (13.2) |
NOTES
Note |
---|
⁽¹⁾ CTWD (Contact Tip to Work Distance). Subtract 1/4 in. (6.4 mm) to calculate Electrical Stickout. |
⁽²⁾ Procedures in these areas are procedures for short circuiting mode using 100% CO2. When using 75% Argon, 25% CO2 for short circuit transfer, reduce voltage by 1 to 2 volts. |