20 lb Plastic Spool SuperGlaze or SuperGlaze HD Aluminum MIG Wire

Diameters / Packaging

Diameters
16 lb Spool
20 lb Spool
1/16 in (1.6 mm) ED038144
3/64 in (1.2 mm) ED038143 ED038141

SuperGlaze® 5356 Plus

MIG (GMAW)

CLASSIFICATIONS:
AWS A5.10 : ER5356

SuperGlaze® 5356 Plus is an enhanced 5356 spool solution giving cleaner welds and improved feeding

DETAILS

SuperGlaze® 5356 PLUS

Experience the next generation of aluminum welding

SuperGlaze® 5356 Plus is Lincoln Electric's proprietary enhanced spool solution. Improved cleanliness, better operator control, and world class feeding by reduced shavings over other 5356 spool products. SuperGlaze® 5356 Plus is used for higher strength welding of 5XXX and 6XXX base materials.

+ Cosmetic Welds

+ Easier Puddle Control

+ Optimal Feeding

Features

  • Enhanced premium 5356 spool solution
  • Cosmetic welds
  • Excellent arc clarity
  • Best feeding performance - reduced shavings

Typical Applications

  • General purpose filler alloy for 5XXX and 6XXX series alloys
  • Trailer Manufacturing
  • Formed truck panels
  • Structural frames in the shipbuilding industry

Shielding Gas

  • 100% Argon Argon / Helium Mixtures Flow Rate: 30 - 50 CFH

Special Features

Disclaimers

Warning -

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

See test result disclaimer

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.10 ER5356

MECHANICAL PROPERTIES

Classification Shielding Gas Polarity Tensile Strength
MPa (ksi)
ER5356 Requirement Not Specified Not Specified 240 (35) min.
Typical Result, As-welded 100% Ar DC+ 250-290 (36-42)

WIRE COMPOSITION

Classification %Al %Be %Cr %Fe %Mg %Mn %Si %Ti %Total Cu %Zn
ER5356 Requirement Remainder 0.0003 max. 0.05 - 0.20 0.40 max. 4.5 - 5.5 0.05 - 0.20 0.25 max. 0.06 - 0.20 0.10 max. 0.10 max.
Typical Result Remainder 0.0002 0.12 0.09 4.9 0.12 0.06 0.09 0.00 0.00

TYPICAL OPERATING PROCEDURES

Diameter Shielding Gas Gas Flow
L/min (CFH)
Polarity CTWD
mm (in.)
Wire Feed Speed
m/min (in/min)
Voltage
volts
Approx. Current
amps
Typical Result 100% Ar 25 (53) DC+ 16 (⁵/₈) 18 (709) 23.3 180
Typical Result 100% Ar 25 (53) DC+ 16 (⁵/₈) 13 (512) 24.3 210
Typical Result 100% Ar 25 (53) DC+ 19 (³/₄) 9 (354) 25.1 280