Blue Max Stainless Wire

Diameters / Packaging

Diameters
33 lb (15 kg) Steel Spool
0.035 in (0.9 mm) MG718035667
0.045 in (1.1 mm) MG718045667
1/16 in (1.6 mm) MG718062667

Techalloy® 718

MIG (GMAW)

CLASSIFICATIONS:
AWS ERNiFeCr-2

TECHALLOY® 718 Metal Inert Gas Wire designed for MIG and TIG welding of 718, 706 and X-750 alloys.

DETAILS

TECHALLOY® 718 ideal for welding high strength aircraft components and liquid rocket components involving cryogenic temperatures, as it can be age hardened to higher strengths operation.

Features

  • This alloy can be age hardened to higher strengths
  • Q2 Lot® - Certificate showing actual wire composition available online

Typical Applications

  • Used for welding alloys 718, 706 and X-750
  • Mainly used for welding high strength aircraft components and liquid rocket components involving cryogenic temperatures
  • General Fabrication

Welding Positions

  • All

Shielding Gas

  • MIG 75% Argon / 25% Helium

Disclaimers

Warning -

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

See test result disclaimer

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.14 ERNiFeCr-2
CWB AWS A5.14 ERNiFeCr-2

WIRE COMPOSITION

Classification %Al %B %C %Cr %Cu %Fe %Mn %Mo %P %S %Si %Ti %Nb+Ta %Ni+Co
ERNiFeCr-2 Requirement 0.20 - 0.80 0.006 max. 0.08 max. 17.0 - 21.0 0.30 max. Remainder 0.35 max. 2.80 - 3.30 0.015 max. 0.015 max. 0.35 max. 0.65 - 1.15 4.75 - 5.50 50.0 - 55.0
Typical Result 0.50 0.005 0.06 17.5 0.02 20.2 0.06 3.04 0.003 max. 0.003 max. 0.04 0.93 5.11 52.5

TYPICAL OPERATING PROCEDURES

Diameter Shielding Gas Polarity Voltage
volts
Approx. Current
amps
.035" (0.9 mm) 75% Ar, 25% He DC+ 26-29 150-190
.045" (1.1 mm) 75% Ar, 25% He DC+ 28-32 180-220
1/16" (1.6 mm) 75% Ar, 25% He DC+ 29-33 200-250