Détails
Lincoln Electric's triple deoxidized premium copper coated MIG wire, SuperArc® L-52® is an excellent choice for making high quality, high toughness welds, even when welding over rust and mill scale
Traits
- A triple deoxidized (Aluminum, Titanium, Zirconium)ER70S-2 solid wire designed for welding over rust and mill scale without sacrificing welding quality
- Very low Nitrogen in the steel makes it easy to achieve impact resistance above 70 ft•lbs @ -20F
- MicroGuard® Ultra provides superior feeding, arc stability and improved protection against corrosion
- Other characteristic features include excellent start properties, extremely low contact tip wear, low levels of spatter and fume emission
- Preferred for all position welding of different sizes of pipe
Applications typiques
- Root, fill and cap pass welding for Piping Industries
- Metal Fabrication
- Power Generation
Positions de soudage
- All
Gaz de protection
- Mixed Shielding Gas|100% CO2
Disclaimers
Des informations de service
Vous pourriez également avoir besoin
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.18 | ER70S-2 |
MECHANICAL PROPERTIES
Classification | Shielding Gas | Polarity |
Yield Strength @ 0.2% Offset
MPa (ksi) |
Tensile Strength
MPa (ksi) |
Elongation
% |
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F) |
---|---|---|---|---|---|---|
ER70S-2 Requirement | 100% CO2 | DC+ | 400 (58) min. | 480 (70) min. | 22 min. | 27 (20) min. |
Typical Result, As-welded | 100% CO2 | DC+ | 440 (63) | 520 (76) | 30 | 104-156 (77-115) |
WIRE COMPOSITION
Classification | %Al | %C | %Cr | %Mn | %Mo | %Ni | %P | %S | %Si | %Ti | %V | %Zr | %Total Cu |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ER70S-2 Requirement | 0.05 - 0.15 | 0.07 max. | 0.15 max. | 0.90 - 1.40 | 0.15 max. | 0.15 max. | 0.025 max. | 0.035 max. | 0.40 - 0.70 | 0.05 - 0.15 | 0.03 max. | 0.02 - 0.12 | 0.50 max. |
Typical Result | 0.07 | 0.04 | 0.06 | 1.10 | 0.01 | 0.03 | 0.003 | 0.003 max. | 0.59 | 0.10 | 0.01 | 0.03 | 0.21 |
TYPICAL OPERATING PROCEDURES
Diameter | Shielding Gas | Polarity |
CTWD
mm (in.)⁽¹⁾ |
Wire Feed Speed
m/min (in/min) |
Voltage
volts |
Approx. Current
amps |
Melt-off Rate
kg/hr (lb/hr) |
---|---|---|---|---|---|---|---|
0.035 in (0.9 mm) | 100% CO2 | DC+ | 12-19 (1/2-3/4) | 5.6-19.8 (220-780) | 19-31 | 105-320 | 1.6-5.7 (3.6-12.6) |
0.045 in (1.1 mm) | 100% CO2 | DC+ | 12-19 (1/2-3/4) | 5.1-15.2 (200-600) | 19-31 | 145-360 | 2.4-7.2 (5.3-15.9) |
NOTES
Note |
---|
⁽¹⁾ CTWD (Contact Tip to Work Distance). Subtract 1/4 in. (6.4 mm) to calculate Electrical Stickout. |