50 lb Can of Lincoln Electric Stick Electrodes

Diameters / Packaging

Diameters

(3) 10 lb Easy Open Can
50 lb Easy Open Can
50 lb Easy Open Can Buy America
ED034040,ED034039
1/8 x 14 in (3.2 x 350 mm) ED032600 ED030893
3/16 x 14 in (4.8 x 350 mm) ED030895 ED034042
3/32 x 14 in (2.4 x 350 mm) ED032599 ED030892
5/32 x 14 in (4.0 x 350 mm) ED030894 ED034041
7/32 x 18 in (5.6 x 450 mm) ED030897 ED034315

Excalibur® 8018-C3 MR®

Stick (SMAW) | ED030892

CLASSIFICATIONS:
E8018-C3

Low Alloy, Low Hydrogen • AWS E8018-C3 H4R

DETAILS

Low alloy stick electrode designed to produce a 1% nickel deposit

Features

  • Designed to produce a 1% nickel deposit
  • Easy strike
  • Effortless slag removal
  • Premium arc performance
  • Meets NACE MR0175 for sour gas applications
  • Test data available for SSC (NACE TM0177) & HIC (NACE TM0284)

Disclaimers

Warning -

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

You May Also Need

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

See test result disclaimer

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.5 E8018-C3 H4R
ISO ISO 2560-B E5518-N2 A U H5
ABS AWS A5.5 E8018-C3 H4R
TUV AWS A5.5 E8018-C3 H4R
CWB CSA W48 E5518-C3-H4

MECHANICAL PROPERTIES

Classification Yield Strength @ 0.2% Offset
MPa (ksi)
Tensile Strength
MPa (ksi)
Elongation
%
Charpy V-Notch
J (ft-lbs) @ -40°C (-40°F)
Hardness Rockwell B
E8018-C3 H4R Requirement 470-550 (68-80) 550 (80) min. 24 min. 27 (20) min.
Typical Result, As-welded 480-540 (70-78) 560-620 (82-89) 25-30 47-159 (35-117) 88-93

DEPOSIT COMPOSITION

Classification %C %Cr %Mn %Mo %Ni %P %S %Si %V Diffusible Hydrogen
mL/100g Weld Metal
1800F H2O - As received 1800F H2O - After 9 hrs at 80F/80%RH
E8018-C3 H4R Requirement 0.12 max. 0.15 max. 0.40 - 1.25 0.35 max. 0.80 - 1.10 0.03 max. 0.03 max. 0.80 max. 0.05 max. 4 max. 0.2 max. 0.4 max.
Typical Result 0.04-0.12 0.02-0.05 0.91-1.14 0.11-0.33 0.81-1.10 0.01-0.02 0.01 max. 0.22-0.44 0.01 max. 1-4 0.1 max. 0.1-0.4

TYPICAL OPERATING PROCEDURES

Diameter Polarity⁽¹⁾ Current
Amps
3/32 in (2.4 mm) DC± 70-110
3/32 in (2.4 mm) AC 80-120
1/8 in (3.2 mm) DC± 90-160
1/8 in (3.2 mm) AC 100-160
5/32 in (4.0 mm) DC± 130-210
5/32 in (4.0 mm) AC 140-210
3/16 in (4.8 mm) DC± 180-300
3/16 in (4.8 mm) AC 200-300
7/32 in (5.6 mm) DC± 250-330
7/32 in (5.6 mm) AC 270-370
1/4 in (6.4 mm) DC± 300-400
1/4 in (6.4 mm) AC 325-425

NOTES

Note
⁽¹⁾ Preferred polarity is listed first.