Lincoln 7018 AC E7018

Diameters / Packaging

Diameters
(4) 5 lb Tube
(6) 1 lb Tube
1/8 x 14 in (3.2 x 350 mm) ED033515 ED033513
3/32 x 14 in (2.4 x 350 mm) ED033514 ED033512
5/32 x 14 in (4.0 x 350 mm) ED033516

Lincoln® 7018 AC-RSP

Stick (SMAW) | ED033515

CLASSIFICATIONS:
E7018 H8

Mild Steel, Low Hydrogen • AWS E7018 H8

DETAILS

Mild steel low hydrogen stick electrode designed for cold re-strike and tacking - Retail Small Packaging (RSP). All RSP products carry AWS compliance. Unlike the standard products, RSP products have no other agencies approvals.

Features

  • AC polarity welding
  • Low open circuit voltage operation
  • Minimal spatter
  • Capable of cold re-strikes

Disclaimers

Warning -

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

See test result disclaimer

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.1 E7018, E7018-H8

MECHANICAL PROPERTIES

Classification Yield Strength @ 0.2% Offset
MPa (ksi)
Tensile Strength
MPa (ksi)
Elongation
%
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F)
Hardness Rockwell B
E7018-H8 Requirement 400 (58) min. 480 (70) min. 22 min. 27 (20) min.
Typical Result, As-welded 480-500 (69-72) 560-590 (81-86) 26-33 31-95 (23-70) 88-91

DEPOSIT COMPOSITION

Classification %C %Cr %Mn %Mo %Ni %P %S %Si %V %Mn+Ni+Cr+Mo+V Diffusible Hydrogen
mL/100g Weld Metal
1800F H2O - As received
E7018-H8 Requirement 0.15 max. 0.20 max. 1.60 max. 0.30 max. 0.30 max. 0.035 max. 0.035 max. 0.75 max. 0.08 max. 1.75 max. 8 max. 0.6 max.
Typical Result 0.04-0.06 0.03-0.04 0.98-1.32 0.01 0.02-0.03 0.018-0.019 0.007-0.013 0.33-0.38 0.02 1.06-1.40 3-6 0.1-0.2

TYPICAL OPERATING PROCEDURES

Diameter Polarity Current
Amps
3/32" (2.4 mm) AC 75-120
3/32" (2.4 mm) DC+ 70-115
1/8" (3.2 mm) AC 105-150
1/8" (3.2 mm) DC+ 100-140
5/32" (4.0 mm) AC 130-200
5/32" (4.0 mm) DC+ 120-185