LINCOLNWELD® 347 has additional niobium to help reduce intergranular corrosion in severe operating conditions.
Features
- The addition of niobium reduces intergranular corrosion in severe operating conditions
- Q2 Lot® - Certificates showing actual wire chemistry available online
- The addition of niobium reduces intergranular corrosion in severe operating conditions
- Q2 Lot® - Certificates showing actual wire chemistry available online
Disclaimers
Service Information
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.9 | ER347 |
ABS | AWS A5.9 | ER347 |
CWB | CSA W48 | ER347 |
MIL | MIL-E-19933E AMD1 | MIL-347 |
WIRE COMPOSITION
Classification | %C | %Cr | %Cu | %Mn | %Mo | %N | %Nb | %Ni | %P | %S | %Si | Ferrite Number (Delong ©) | Ferrite Number (WRC-1992 ©) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ER347 Requirement | 0.08 max. | 19.0 - 21.5 | 0.75 max. | 1.0 - 2.5 | 0.75 max. | Info. Only | 10xC - 1.0 | 9.0 - 11.0 | 0.03 max. | 0.03 max. | 0.30 - 0.65 | Info. Only | Info. Only |
Typical Result | 0.05 | 19.6-20.0 | 0.02-0.11 | 1.7-1.8 | 0.05-0.21 | 0.03-0.05 | 0.6-0.7 | 9.0-10.7 | 0.02 | 0.01 max. | 0.43-0.50 | 6-13 | 5-13 |
TYPICAL OPERATING PROCEDURES
Diameter |
Voltage
volts |
Approx. Current
amps |
---|---|---|
3/32" (2.4 mm) | 28-33 | 275-350 |
1/8" (3.2 mm) | 29-32 | 350-450 |
Lincolnweld® P2000™ | ||
Lincolnweld® P2000™ |