Fleetweld 5P 14 Stick Electrode in 10 lb cans"

Diameters / Packaging

Diameters
(3) 10 lb Easy Open Can
3.2 x 350 mm (1/8 x 14 in) ED032622
4.0 x 350 mm (5/32 x 14 in) ED032623

Pipeliner® 19P

Stick (SMAW) | ED032622

CLASSIFICATIONS:
E10018-G H4R

Low Alloy, Low Hydrogen, Pipe • AWS E10018-G H4R

DETAILS

Low alloy stick electrode designed for vertical up fill and cap pass welding of up to X80 grade pipe

Features

  • Q2 Lot® - Control and Tested - Lot certificate available online
  • Charpy V-Notch impact toughness tested to -46°C (-50°F)
  • vertical up capability on X80 grade pipe

Disclaimers

Warning -

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

You May Also Need

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

See test result disclaimer

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.5 E10018-G-H4R

MECHANICAL PROPERTIES

Classification Yield Strength @ 0.2% Offset
MPa (ksi)
Tensile Strength
MPa (ksi)
Elongation
%
Charpy V-Notch
J (ft-lbs) @ -45°C (-50°F)
E10018-G-H4R Requirement 600 (87) min. 690 (100) min. 16 min.
Typical Result, As-welded 660-750 (95-109) 730-800 (106-115) 21-28 73-125 (54-92)

DEPOSIT COMPOSITION

Classification %B %C %Cr %Cu %Mn %Mo %Ni %P %S %Si %V Diffusible Hydrogen
mL/100g Weld Metal
1800F H2O - As received 1800F H2O - After 9 hrs at 80F/80%RH
E10018-G-H4R Requirement 0.30 min. * 0.20 min. * 1.00 min. * 0.20 min. * 0.50 min. * 0.03 max. 0.03 max. 0.80 min. * 0.10 min. * 4 max. 0.15 max. 0.4 max.
Typical Result 0.0002 max. 0.038-0.049 0.02-0.04 0.01-0.07 1.54-1.89 0.42-0.45 2.06-2.28 0.01 0.01 0.40-0.54 0.01 max. 1-3 0.02-0.10 0.1-0.3

TYPICAL OPERATING PROCEDURES

Diameter Polarity⁽¹⁾ Current
Amps
3.2 mm (1/8 in) DC+ 80-155
3.2 mm (1/8 in) AC 80-160
4.0 mm (5/32 in) DC+ 130-210
4.0 mm (5/32 in) AC 140-215

NOTES

Note
* To meet the requirements of a "G" classification, the chemical composition of the weld deposit must meet the minimum requirement for one or more of these elements.